Overview
The XF40-Di is an explosion-protected Dual Imaging fixed camera station designed for continuous monitoring and surveillance in hazardous areas in onshore, offshore, marine and heavy industrial environments.
It is constructed from electropolished 316L stainless steel for maximum corrosion protection and is fitted as standard with sunshields and an integral thermostatically controlled heater element.
It utili is a 36X analogue block camera and a thermal core for monitoring in complete darkness and adverse conditions such as prevaillant fog and smoke. These are switched by standard RS485 Pelco commands from one camera to the other to match conditions or for process monitoring as required.
It can be specified with an integral wiper for the D-N camera window or can used the XWP pressurised washer pump for cleaning of the Day-Night Camera window. There germanium is protected by a 316L stainless steel grill.
A 3m conduit tail can be specified as standard with options from1.5 to 15m to suit site requirements.
It can also be used in conjunction with a range of Oxalis Termination Enclosures (Ex e) or Transmission Systems (Ex d) for power supply, powered devices and transmission equipment.
The XF range can be used in conjunction with Oxalis video management solutions but is designed be compatible with most common Video Management Systems
Features
Explosion Protected for use in Onshore, Offshore, Marine & Heavy Industrial Applications
ATEX, UL, IECEx, CSA, CCE, INMETRO, CNEX and GOST-R Approvals
Dual Cameras: Switchable 36X D/N and Thermal Core for Continued “All Conditions" Viewing
Integral Fibre Transmission Option
24VAC Supply Voltage
All Electro-polished 316L Stainless Steel Construction
Optional Integral Wiper and Ex Washer Tank
Integral Multi-Protocol Telemetry Receiver and interface for FLIR operation over standard Pelco commands
Certification
Certified Part Number
2410-04/2420-01 /2410-05/2420-01 (Wiper)
Area Classification
Zones 1, 2, 21 and 22 (ATEX / IECEx / INMETRO) / Class 1, Zone 1 (North America and Canada cLCus)
Equipment Coding (ATEX)
II 2 G Ex d op pr IIC T4 (T5 & T6 Available on Request) II 2 D Ex tb IIIC T135°C Db IP6x
Equipment Coding (IECEx)
Ex d IIC T4/5* -60°C ≤ Ta ≤ +60°C Gb Ex tb IIIC T130°C Db IP6x
Equipment Coding (INMETRO)
Ex d IIC T4/5* -60°C ≤ Ta ≤ +60°C Gb Ex tb IIIC T130°C Db IP66/67
Equipment Coding (US - LCus)
Class 1 Zone 1 AEx d IIC T4/5* LC13A11396 Gb -60°C ≤Ta ≤ +60°C
Equipment Coding (Canada - cLC)
Ex d IIC T4/5* LC1311396 -60°C ≤Ta ≤ +60°C
Equipment Coding (China – CNEX)
Ex d IIC T4/T5/T6 GB / Ex d IIIC 135°C Db IP6X
Equipment Coding (Class – DIV)
Class I, Division 1, Groups B, C, D, -60°C≤Ta≤60°C / Class II, Division 1, Groups E, F, G
Certificate Number (ATEX)
ITS08ATEX15950X / ITS08ATEX15927X
Certificate Number (IECEx)
IECEx ITS 10.0053X / IECEx ITS 10.0063X
Certificate Number (INMETRO)
TUV 12.1080 / TUV 12.1081
Certificate Number (US – LCus)
11396 – 1S – UL
Certificate Number (Canada – cLC)
11396 – 1S - CSA
Certificate Number (Russia – GOST-R)
POCC GB.ГБ.B00659
Certificate Number (India – CCE)
P306928/1/2
Certificate Number (China – CNEX)
132.2980X / 13.2981X
Certificate Number (Class – DIV)
11671 – 1S
所有評(píng)論僅代表網(wǎng)友意見,與本站立場(chǎng)無關(guān)。